321 Research Parkway, Meriden, CT
Building Size:49,419 SF Class A office building
Land Area:5.26 acres
Construction:three story, steel-framed office building
Roof:The roofing system consists of a gravel surface built-up membrane over insulation. The roof is framed with 16-inch deep open web joists supported by 16-inch deep wide flange steel beams and wide flange steel columns.The roof decking is 1 1/2 inch deep painted wide rib steel roof deck.
Year Built:1985
Parking:206 parking spaces, 4 handicap
HVAC:Three roof-top, mounted package units - 30-ton, 50-ton, and 60-ton provide cooling. A gas-fired, hot water (modular type), cast iron boiler serves as the heating system.
Fire Protection:The building is served with a 6 inch fire service with the required backflow preventer. The building is protected by a 4 inch combination standpipe/sprinkler riser in the south stairwell. Each floor has a zone valve and a Class II fire hose and valve cabinet in the stairwell. No fire pump is required because street water is 110 psi.
Electrical:Main service rated 600 amps, 480/277 volts, 3-phase, 4-wire. Available power is 7.6 watts/SF.
Elevator:There is one public elevator serving the building. The motor is fed with a 60 Amp, 480 volt, 3-phase system to the motor controller within the elevator machine room.
Contact:Please contact David Barnes, CB Richard Ellis, at 860.987.4782 or Carter Winstanley at 978.287.5000